Flowserve Valtek Mark One Three-way Control Valve Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per Hardware Flowserve Valtek Mark One Three-way Control Valve. Flowserve Valtek Mark One Three-way Control Valve User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 4
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
3-1
Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611
Valtek Three-way
Control Valves
Valtek No. 49013
GENERAL INFORMATION
The following instructions are designed to assist in
unpacking, disassembling, reassembling and trou-
bleshooting Valtek
®
three-way control valves. Product
users and maintenance personnel should thoroughly
review this bulletin in conjunction with Installation, Op-
eration, Maintenance Instructions 1 (Mark One and Two
Control Valves) prior to installing, operating or perform-
ing any maintenance on the valve.
This publication does not contain information on Valtek
positioners. Refer to the appropriate Installation, Op-
eration, Maintenance Instructions for installing, main-
taining, troubleshooting, calibrating, and operating
Valtek positioners.
To avoid possible injury to personnel or dam-
age to valve parts, WARNING and CAUTION
notes must be strictly adhered to. Modifying
this product, substituting nonfactory parts, or
using maintenance procedures other than out-
lined could drastically affect performance and
be hazardous to personnel and equipment, and
may void existing warranties.
Three-way valves are used for either converging or
diverging service. For interchangeability, a standard
globe valve converts to a three-way valve with the
addition of a three-way adaptor, upper seat ring, two
upper seat gaskets, and a three-way plug. Its operation
is similar to a standard Mark One globe valve.
Unpacking
1. While unpacking the valve, check packing list against
the materials received. Lists describing valve and
accessories are included in each shipping container.
2. When lifting the valve from the shipping container,
position the lifting straps to avoid damage to the
tubing and mounted accessories. Valves provided
with a lifting ring (up to 6-inch) may be lifted by the
actuator lifting ring. On larger valves, lift the valve
using straps through the yoke legs or if provided,
lifting brackets bolted to bonnet stud.
3. In the event of shipping damage, contact your ship-
per immediately.
4. If any problems arise, contact your Flowserve
representative.
Troubleshooting
If difficulty is suspected with the control valve, check the
following:
1. Make sure the valve has a sufficient air supply.
2. Check for air leaks in the air supply, instrument signal
system, and positioner.
3. Make sure the packing isn’t too tight by lossening the
gland flange nuts and retightening to just over finger-
tight.
CAUTION: Do not overtighten the packing. This
can cause excessive packing wear and high stem
friction which may impede plug movement.
Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - Control Valves

3-1Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611Valtek Three-wayControl ValvesValtek No. 49013GENERAL INFORMATIONThe following

Pagina 2 - Reassembling Three-way Valves

3-2Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 86112. Install new seat ring gasket, lower seat ring andretainer.3. Insert the plu

Pagina 3 - Figure 1:

3-3Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611Figure 1:Mark One Three-way Valve Body SubassemblyNOTE: Item numbers correspo

Pagina 4

3-4Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611FCD VLAIM003-03 © 2000 Flowserve Corporation. Flowserve Corporation

Commenti su questo manuale

Nessun commento