Flowserve ISC Series Manuale Utente Pagina 12

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 16
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 11
12
4.2 For dual pressurized seal (double seal) operation, supply a clean
compatible barrier uid to the inlet port at a pressure at least
170 kPa (25 psi) above the seal chamber pressure. See Figure 9.
The pressure of the barrier uid must not exceed the recommended
maximum pressure. Flowserve can supply information on barrier
uid ow requirements based on seal size, product temperature,
barrier uid characteristics, and shaft speed.
4.3 For dual unpressurized (tandem seal) operation, supply a clean
compatible buffer uid to the inlet port at a pressure below the seal
chamber pressure. See Figure 10. The pressure in the seal
chamber must not exceed the recommended maximum pressure.
Flowserve can supply information on buffer uid ow requirements
based on seal size, product temperature, buffer uid characteristics,
and shaft speed.
Double ISC with Supply Tank Figure 9
Bypass
Flush to
Gland
Flush Port
Supply Tank
Assembly with
Cooling Coils
1.2 m (4 feet)
maximum
Pressure
Source
0.45 - 0.6 m
(1.5 - 2 feet)
minimum
Orifice
Option
Vedere la pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Commenti su questo manuale

Nessun commento