Channel 4 DI_ACTUATOR_FAULTS_1_CHAN Value
Monitor Relay 0x01
Valve Jammed 0x02
Manual Moved 0x04
Over Torque 0x08
Phase Error 0x10
Over Temp 0x20
Monitor Relay + Valve Jammed 0x03
Monitor Relay + Manual Move 0x05
Monitor Relay + Over Torque 0x09
Monitor Relay + Phase Error 0x11
Monitor Relay + Over Temp 0x21
Monitor Relay + Valve Jammed + Manual Move 0x07
Monitor Relay + Valve Jammed + Phase Error 0x13
Monitor Relay + Valve Jammed + Over Temp 0x23
Channel 5 – Actuator Faults 2
The Channel 5 Discrete Input function block, DI_ACTUATOR_FAULTS_2_CHAN, makes actuator faults
available to other function blocks. The reported faults include:
Valve jammed in motion due to a tripped torque switch
Valve was manually moved with the actuator handwheel
An over torque condition occurred while traveling in the open direction
An over torque condition occurred while traveling in the close direction
Loss of electrical phase at the motor
Thermal overload indicating the motor has overheated and the thermistor has opened; time is
required for the motor to cool and reset the thermistor.
Channel 5 DI_ACTUATOR_FAULTS_2_CHAN Value
Thermal Overload 0x01
Phase Error 0x02
Valve Jammed 0x04
Manual Moved 0x08
Open Torque Switch Fault 0x10
Close Torque Switch Fault 0x20
Thermal Overload + Manual Moved 0x09
Thermal Overload + Phase Error 0x03
Thermal Overload + Valve Jammed 0x05
Open Torque Switch Fault + Manual Moved 0x18
Close Torque Switch Fault + Manual Moved 0x28