2.12 Slideandrepositionthebearing
assemblyagainstthemounting
ange.Securethehousingtothe
mountingangeusingfour(4)
bolts.Tightenboltstoatorque
valueof33N-m(25ft-lbs).Verify
themetal-to-metalcontactatthe
housingjointisunchangedfrom
thepreviousstep.
2.13 Injecthightemperaturegrease
directlyintothegreaseport
locatedonthecarrierassembly.
Fillwithgreaseuntilgreaseis
observedescapingfromthe
bearingwiperseals.Installa
exiblelubricationlinetothe
carrierassemblygreaseport
toenablegreasingfromthe
ground during operation.